# CT colormaps

> Hounsfield units and the ct_ colormaps, which carry their own display window for each tissue.

Computed tomography (CT) stores calibrated intensities, unlike most MRI
sequences, whose signal is relative. CT uses Hounsfield units (HU): air is
about -1000 HU, water 0 HU, and dense bone can exceed +1000 HU. Most soft
tissues (gray and white matter, muscle) fall between 0 and 40 HU, and an
intravenous contrast agent briefly brightens blood and enhancing tissue.

Because the values are standardized, NiiVue ships colormaps tuned to
particular tissues. Each name starts with `ct_`, and each carries its own
display window, so choosing one also sets `calMin` and `calMax`
([Colormaps and contrast](https://niivue.com/docs/guide/colormaps/) explains how a map's window
combines with one you pass). Try them on an abdominal scan:

```js
await nv.loadVolumes([{ url: 'CT_Abdo.nii.gz', colormap: 'ct_kidneys' }])
await nv.setVolume(0, { colormap: 'ct_bones' }) // window becomes 180..600 HU
const ctMaps = nv.colormapNames('continuous').filter((n) => /^ct_/i.test(n))
```

The other controls in the demo:

- **Clip dark**: `nv.volumeIsAlphaClipDark = true` makes voxels below
  `calMin` transparent, so air and fat no longer hide the render.
- **Gamma**: `nv.gamma` brightens (above 1) or darkens (below 1) the 3D
  render's colors without changing how much each sample occludes.
- **Render**: `nv.volumeRenderMode` picks a ray-marched render
  (`VOLUME_RENDER_MODE.COMPOSITE`) or the three crosshair planes
  (`VOLUME_RENDER_MODE.SLICES`); `nv.volumeIllumination` shades the march,
  from matte (0) to glossy (0.6).